SS HTST MILKPASTEURIZERMODULE COMPLETE WITH ACCESSORIES & (HOT WATER OPERATED)
MOC: SS 304
Design Parameters:
Product:WholeMilk :16.5%
RawMilk Feed Temperature : 35/4C
Milktake off temperature to filter / separator :45C
Milktake off temperature to Homogenizer :65/72C
MilkPasteurization temperature : 80/85C
Holdingtime for pasteurization: Minimum 20 Sec.
Finishedmilk discharge temperature :80/4C.
Heatregeneration :95%
ChilledWater Flow Rate : 1000 LPH
ChilledWater Feed Temperature : 1.0C.
HotWater Flow Rate : 750 LPH
HotWater Feed Temperature : 83/95C
ProcessOperation:
Pasteurization temperaturecontrol and flowrate (bymechanical flow controller) will be manually. Sequencing of production, sanitizationand CIP willbe manual. Detergentaddition in the balance tank andconcentrationmonitoringwillbemanual.CIP flowrate
Will be approximately 1.2 timesof the product flow rate.
Scope of Supply:
1. Balancetank, 1 Nos. Capacity, 150 L, MOCSS304,with float and top cover and three legs.
2. Feedpump, 1Nos. Centrifugal pump allwetted parts in SS 304, SMS connectionswithsingle shaft seal with motor of Crompton make.
3. Flowcontroller (Diapharm Type): 1 Nos.Mechanical flow controller, to control theproductflow rate. MOC SS 304 with Unions at ends.
4. PlateHeat Exchanger,1 Nos.
Frames: MS cladded with SS 304
Plates:ALLOY 316/0.5 Thk
Gaskets:NBRCLIP ON
No of sections: Four
Design temp : 110 deg C
Design/testpr.:6/8Bar
Holding tube (20 Sec.), 1 Nos. Holding tube will be designedfor the specified holding time consideringthe CIP clean abilityand fastestparticle velocity. MOC is SS 304. Holding tube willbe made up of pipes and to match the internal surfaces get thebesthygienicconstruction.
All SS welding joints are to beground smooth and polished to180grits. AllSSsurface
RUPESH EQUIPMENTS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |